Description
PERMAQ® PICO VARIO
PERFECTLY PURE WATER INSTALLATION
Designed for a direct connection to one or several point-of-use.
-
Real tankless reverse osmosis
This online model is equipped with an integrated frequency controller and pressure gauge, which gives users the desired flow rates at a fixed set pressure.
-
Highest hygiene
Full-fit membrane modules have no “dead zone“ areas where water stagnates and biofouling occurs -> 100% full flow
-
Easy installation
NO pressure tank is required
-
Fields of applications
Permaq Pico is useful for climatization, cooling water, lab-water, laundries, dishwashers, steam installations, air humidifiers, laboratories and process water of all kinds.
PERMAQ PICO VARIO | 40 | 50 | 60 | |
Connection width | DN | 20/25 | 20/25 | 20/25 |
Permeate output | m³/h | 0.15–0.45 | 0.25–0.9 | 0.3–1.25 |
WCF | % | 75-80 | 75-80 | 75-80 |
Salt retention rate | % | >98.5 | >98.5 | >98.5 |
Order no. | 13238 | 13240 | 13242 | |
Order no. HR version | 13239 | 13241 | 13243 | |
BWT PERMAQ® Pico Vario Dimensions | Type | 40 / 40 HR | 50 / 50 HR | 60 / 60 HR |
Width x Depth | mm | 400 x 510 | 400 x 670 | 400 x 670 |
Height | mm | 1500 | 1500 | 1500 |
Operating weight, approx. | kg | 115 | 140 | 150 |
What means high rejection (HR)?
▪ Improved salt rejection >99% accompagnied by reduced flow rate
▪ Solution for high TDS feed water
▪ Solution for applications, which requires low permeate conductivity
BWT PERMAQ Pico 40-90 Vario
▪ Direct-connect - real online solution without membrane pressure tank
▪ Incl. booster pump
▪ Modulating permeate flow rate 60 – 2,050 l/h
▪ Constant permeate delivery pressure during consumption
▪ Adjustable permeate pressure between 3.0 and 7.0bar
▪ Different RO membrane types
▪ Full-fit-RO
▪ Hygiene- and Interval flush
▪ Dead zone reduced multi-block-connection
technology
▪ Ultra-compact unit with stainless steel frame and coated housing
▪ Remote data access with optional BUS-
communication module (Ethernet, Profinet, ...)
Important points
▪ Feed TDS < 1’000mg/l
▪ Total iron & manganese concentration < 0.1mg/l
▪ Oxidysing agents/Total chlorine < 0.05mg/l
▪ SDI < 3.0 %/min
▪ Hardness 0°dH (with AS dosing < 25°dH)
▪ Silicate
▪ Recovery resp. WCF influences the concentration factor
▪ Do the feed water specifications deviate from the tolerable values (product data sheet)? If yes, a technical design review, based on a water analysis is required.
Downloads
BWT PERMAQ® PICO Vario Data sheet
Installation and Operating Manual EN | BWT Permaq Pico and Permaq Pico Vario