Description
AQA therm MOVE Power
- Perfect low-salt water, continuously monitored and independent of the raw water quality
- Powerful up to 400 l/h and at least 80,000 liters with just one membrane insert (depending on inlet pressure and temperature)
- Mobile and manoeuvrable thanks to compact design and low weight
- Heating water without chemicals for sustainable occupational safety, consumer protection and drinking water protection
- Self-explanatory with display and APP
- Documentation of the filling and water parameters in the APP
- Diaphragm replacement in no time, clean and without tools
- Unattended filling up to the desired cut-off pressure
AQA therm MOVE Power defines mobile heating filling according to new standards. The mobile complete unit is more precise and economical than ever before. With a conductivity of approx. 600 µS/cm and 20 °dH, the new movement on the heating market guarantees up to 80 m 3 of filling water and saves the expensive use of 1,000 liters of ion exchange resins or harmful acids and alkalis. This relieves both the environment and the wallet, so perfect heating water is affordable for everyone. Another plus: thanks to its so-called “Speed-Connection-System”, a simple membrane change can be carried out by the user himself.
AQA therm MOVE Power is a mobile and stationary reverse osmosis system for generating low-salt water and is suitable for filling heating and cooling systems according to VDI 2035 and ÖNORM H5195-1. The product is equipped with an integrated display and four control buttons. This gives the user a quick overview of all system parameters. The functionality of the system is expanded using the “BWT RO” APP. The APP can be loaded onto your smartphone, tablet, etc. The connection to the system is via Bluetooth. It allows an overview of all current operating parameters. Various settings of system parameters and service intervals can be made with it.
Depending on the settings, the user sees the current parameters in the middle of the display during operation:
- Daily liter counter [l]
- Current flow [l/h]
- System back pressure [bar]
The following data is continuously displayed on the main screen:
- pump pressure [bar]
- Conductivity permeate [μS/cm] or [ppm]
- Water temperature [°C]
- Set switch-on and switch-off pressure [bar] of the system to be filled
Technical specifications
- Nominal connection width | DN/inch | DN20 / 3/4″
- Pipe water connection | DN | 20
- Connection for waste water | DN | 6
- Connection for outlet water | DN | 20
- Nominal pressure (PN) | bar | PN10
- Max. operating pressure | bar | 9
- Inlet water supply pressure, min. – max. | bar | 1.5 – 4
- Water temperature, min./max. | °C | 5 – 25
- Ambient temperature, min./max. | °C | 5 – 40
- Outlet water capacity at 15 °C with free discharge, at start of service life | l/h | Approx. 360
- Outlet water capacity at 15 °C and 2.5 bar counter-pressure, at start of service life. | l/h | Approx. 320
- Outlet water capacity at 15 °C with free discharge, at end of service life, approx. | l/h | 300
- Outlet water capacity at 15 °C and 2.5 bar counter-pressure, at end of service life, approx. | l/h | 250
- Outlet water conversion factor | % | < 50
- Salt retention rate, min. | % | 95
- Capacity per membrane cartridge | m³ | 40
- Protection class | IP | 54
- Power supply | V/Hz | 230 / 50
- Connected load, max. | W | 450
- External fuse | A, time-delay | 2 x 2.0
- Pump capacity | m³/h | 0.8
- High-pressure pump motor capacity. | W | 350
- Connection load, pump | VAC / A | 230 / 2.3
- Dimensions without wheels, width x height x depth | mm | 355 x 795 x 290
- Operating weight, approx. | kg | 44
- Net weight (without packaging) | kg | 38.6
The water fed into the product must be cold water that conforms to statutory drinking water quality requirements and the requirements in the “Inlet water” data below.
- Inlet water temperature, min. to max. | 5 °C – 25 °C
- Silicate (SiO2 ) | ≤ 15 mg/l
- Oxidants, chlorine | ≤ 0.05 mg/l
- Iron and manganese (Fe+Mn) | ≤ 0.05 mg/l
- Salt content, total dissolved solids (TDS) | ≤ 1000 mg/l
- Carbonate hardness | < 18 dH
- Silt Density Index (SDI) | ≤ 3.0%/minute
- pH value of the inlet water, min. – max. | pH 5 – pH 10