What is UV disinfection?

Disinfection generally means a reduction of around 99.999% of the pathogens present in the water. A dosage level of 400 J/m² is required to achieve this level of disinfection. The operational settings of the Bewades systems are calculated using numerical computer simulation, guaranteeing a UV dosage of at least 400 J/m². This dosage level has been biodosimetrically proved in the ‘N’ range systems and certified in accordance with ÖNORM M5873-1.

The number of UV disinfection systems installed is growing steadily and this ecologically-sound process is being used in an increasing range of applications owing to its extensive functionality and ease of use.

The BWT Bewades UV disinfection process will have no effect on the:

  • Water hardness
  • pH value
  • Taste
  • Smell
  • Colour of the treated water

Bewades N

Safe desinfection according to the norm.

Intended use

The Bewades N UV disinfection unit is used to disinfect drinking water. In general, disinfection means a 99.99% reduction in the pathogenic germs found in drinking water (4 log levels).

The standard unit is always used when highly controlled microbiological requirements are applied to the water and a certified unit (e.g. ÖNORM M 5873-1, DVGW Worksheet W294) is required

For all series N BWT Bewades UV disinfection units, a UV fluence (dosage) of 400J/m2 has been biodosimetrically verified. This leads to a loss of the ability of the micro-organisms in the water to multiply (reproductive cell death), so they no longer pose a danger to human health.

The UV disinfection process does not change the chemistry, pH value, colour or taste of the water. 

In Austria, the unit must be operated in accordance with ÖNORM M 5873-1.

In Germany, the unit must be operated in accordance with the DVGW Worksheet W294 part 1 (see also TrinkwV §11).


MADE IN GERMANY

Technical specifications:

  • Sophisticated microprocessor based UV control II - easy to use
  • Validated sensor technology for highest operational safety
  • Electronic ballasts for a long lamp life and to compensate voltage fluctuations 
  • CFD optimized hydraulically design ensures safe water disinfection and saves energy costs
  • According to the stringent, internationally recognized standards of the German Technical and Scientific Association for Gas and Water (DVGW)

Bewades

Type

200W200/ 17 N 

390W130/ 27 N 

810W270/ 40 N 

1080W270/ 50 N

Certified in compliance with ÖVGW / DVGW


x

x

x

x

Nominal connection width

DN

R 2"

89 150 200

Volume flow, max. 400 J/m2 at T100 = 80%

m3/h

16,7

47,8

181,9

251,0

Max. operating pressure

bar

10

10

10

10

Water temperature min. - max.

°C

5 - 65

5 - 65

5 - 65

5 - 65

Ambient temperature min. - max.

°C

5 - 40

5 - 40

5 - 40

5 - 40

Emitter output per unit

W

200 130 270 270

Expected emitter service life (dependant on operating conditions)

h


10000 -

14000  

UVC output per unit

W

76 52 89 89

Power supply

V/Hz


230/50/60



Protection class



IP54



Required power supply capacity

W

220 450 850 1130

Number of emitters


1 3 3 4

Order number ÖVGW-certified


23308

23356

23365

23366

Order number DVGW-certified


23353

23354

23289

23299